RESOURCES

Night Vision Glossary

Find the main technical terms used in the world of night vision and image intensifier tubes.

A
Automatic shut-off Automatic shutdown

Function that automatically cuts power to a device or tube in certain situations, for example when a pod is raised, to limit power consumption and unnecessary light exposure to the tube.

Autogating Auto-gating

Technology that rapidly modulates the tube's power to maintain a usable image when brightness changes suddenly. It improves performance against intense light sources and in urban environments.

B
Binocular Binocular NVG

A night vision device with two optical channels, one for each eye. It generally offers better viewing comfort than a monocular and can improve natural perception of the scene.

Blooming Glare / extended light halo

Excessive extension of an intense light source in an image. Significant blooming can obscure part of the scene around the source and reduce the readability of details.

Bruit de motif fixe NFF

Fixed-pattern noise that may be noticeable in the image, especially in certain low-light conditions. It remains associated with the tube structure and does not move with the scene.

C
Collimation Optical alignment

Adjusting the optical alignment of a system, particularly important for binoculars. Good collimation ensures the two images are properly superimposed and reduces eye strain.

Contrast Contrast

The system's ability to differentiate between nearby areas in terms of brightness. Good contrast makes it easier to identify shapes and details in a night scene.

Cosmetic Zones Cosmetic zones

Conventional division of the tube image into concentric zones used to qualify the position of cosmetic defects. The central zone is generally considered the most critical for observation.

Cosmetic Zones
D
Diopter Diopter adjustment

Optical adjustment allowing the sharpness of the eyepiece to be adapted to the user's visual acuity, in order to obtain a clear image without external visual correction.

Distortion Distorsion optique

Geometric distortion of the image produced by the optical system. This can be seen in straight lines that appear curved towards the edges of the field.

Depth of field Profondeur de champ

The range of distances that appear acceptably sharp without changing the focus. It depends in particular on the lens design, its aperture, and the focusing distance.

E
EBI Éclairement du fond équivalent

Measurement of the tube's intrinsic luminous noise level in the dark, generally expressed in µlx. A low value is desirable to maintain good performance in extremely dark environments.

A high value reduces contrast and overall image quality.

Eye relief Eye relief

The distance between the eyepiece and the eye that allows the entire image to be viewed correctly. A long eye relief makes it easier to use with safety glasses or a visor.

Eyepiece Ocular

Optical assembly located on the user side. It allows observation of the image produced by the phosphor screen and usually includes dioptric adjustment.

Exit pupil Exit pupil

The area outside the eyepiece where the eye must be positioned to correctly receive the image. Its diameter and position influence comfort and tolerance to eye placement.

F
Field of View (FOV) Champ de vision

Angle of view visible through the device, expressed in degrees. A wider field of view allows more of the environment to be observed without moving one's head.

Fisheye Wide-angle effect

A type of distortion that gives an image a bulging or curved appearance, particularly noticeable at the edges. It can become more pronounced as the field of view increases.

FOM Figure of Merit

Index obtained by multiplying the tube resolution, expressed in lp/mm, by its signal-to-noise ratio (SNR). FOM allows for quick comparison of certain performances, but does not alone summarize the overall quality of a tube.

G
Grillage à poules Screen Door Effect

Very fine pattern that may appear under certain lighting conditions, resembling a grid or mesh. It is related to the internal structure of the microchannel plate.

Generation 1 Jan 1

First generation of image intensification technologies. It offers significantly lower performance than modern generations, with more distortion and limited amplification.

Generation 2 / 2+ Gen 2 / Gen 2+

Family of tubes that notably use a microchannel plate (MCP) to amplify electrons. Modern "2+" versions can achieve very high performance in resolution, SNR, and sensitivity.

Generation 3 Gen 3

A family of tubes historically characterized by the use of a gallium arsenide photocathode. The notion of "generation" describes a technological architecture and is not sufficient, on its own, to determine the actual performance of a tube.

H
Halo Halo

Diameter of the luminous zone that forms around an intense point source. A lower halo value generally improves the readability of the scene around the lights.

I
Infrared illuminator IR illuminator

Infrared light source used to illuminate a scene when ambient light is insufficient. This light is invisible or barely visible to the naked eye, depending on its wavelength, but can be detected by a compatible night vision system.

L
Light amplification Amplification lumineuse

The ability of a light intensifier to convert a very dimly lit scene into a visible image. It depends, in particular, on the photocathode, the MCP, the gain, and the available light level.

Lueur de bord Edge glow

Abnormal bright area appearing on the edge of the field of view. This is a tube defect that can be permanent or appear under certain conditions.

Light intensifier Image Intensifier Tube / IIT

An electro-optical tube that converts photons from a dimly lit scene into electrons, amplifies them, and then reconverts them into a visible image on a phosphor screen.

LP/mm Paires de lignes par millimètre

A unit used to express the resolution of an intensifier tube. It indicates the number of distinct black and white line pairs that can be resolved per millimeter.

M
Manual gain Manual gain

A function allowing the user to directly adjust the tube's gain level and thus the image brightness. This can be useful for adapting visual comfort to observation conditions.

MCP Microchannel plate (MCP)

A component consisting of a very large number of microchannels that multiply the electrons emitted by the photocathode. The MCP is one of the essential elements for the amplification in a modern tube.

Monocular Monocular

Night vision device using a single optical path and a single intensifier tube. It can be used in front of one eye, leaving the other eye free.

N
Noise Noise

Random variations in brightness in the tube image, giving it a grainy or shimmering appearance. The noise mainly stems from the random nature of photons, which is amplified by the tube. It becomes more visible when the light is low and limits the sharpness of details.

The signal-to-noise ratio (SNR) allows it to be quantified.

NIR / near-infrared Infrared / Near-Infrared

Spectral range beyond visible red. Night vision tubes typically have sensitivity that extends into the near infrared, which notably allows the use of IR illuminators.

NVG / NOD Night Vision Goggles / Night Observation Device

Commonly used English abbreviations for Night Vision Goggles (NVG) and, more broadly, Night Observation Devices (NOD).

O
Objective Objectif

An optical assembly located on the scene side. It collects available light and forms the image on the photocathode of the intensifier tube.

P
Point of emission Point of issue

An abnormal defect that may develop over time and generally indicates that the tube is nearing the end of its life. 

It appears as a small, fixed bright spot visible in the image and generated by the tube itself.

Profit Luminance gain

Ratio between the luminance received by the tube and the luminance produced on the phosphor screen. It partly determines the apparent brightness of the resulting image.

Phosphorus P43 Phosphore vert

Phosphor producing a green image. It offers high contrast and has historically been one of the most common display technologies in night vision.

Phosphorus P43
Phosphorus P45 White phosphorus

Phosphor producing an image perceived as white or blue-gray. It is appreciated for a more natural visual rendering and a different observation comfort compared to green phosphor.

Phosphorus P45
Photocathode Photocathode

Photosensitive surface located at the entrance of the tube. It converts incoming photons into electrons. Its spectral sensitivity plays a major role in very low-light performance.

Photocathode sensitivity Photocathode responsivity

The photocathode's ability to convert incident light into electrons. It is generally characterized under normalized spectral conditions and contributes to low-light performance.

R
Resolution Resolution

Tube's ability to reproduce fine details in an image. For an image intensifier, it is generally expressed in line pairs per millimeter (lp/mm).

S
Sans film Film-free tube

Tube architecture in which the classic ion barrier is not used. This design is notably associated with some Generation 3 tubes and aims to optimize photocathode performance.

Scintillation Scintillation

The grainy and sparkling appearance of the image when the number of available photons becomes very low. The darker the scene, the more noticeable this noise can become.


It is also sometimes called the snow effect » (in English « snow » or « sparkle »)

Signal-to-noise ratio Rapport signal/bruit

Tube signal-to-noise ratio. It expresses the ability to distinguish useful information from electronic and visual noise. A high value is particularly important in very low light environments.

T
Taches noires Blackheads / blemishes

Small dark areas visible in the tube image. Intrinsic to the manufacturing process, they generally result from defects or particles inside the intensification system and are assessed according to their size and position in the image. These defects do not change over time.

Most Photonis civilian tubes, such as the ECHO, ECHO+, OPS4 and OPS4+, have them.

Do not confuse them with dust, which can be removed by cleaning.

Taches noires
V
Vignetting Vignetting

Decrease in brightness or loss of image toward the edges of the field of vision. This can be caused by the optical system, incorrect eye positioning, or a mechanical limitation of the optical path.